Same lesson, with the figures in motion.
Cell Counting with a Microscope (Neubauer-improved)
Count exactly how many cells you have (cells/mL) and how many are alive (viability %) — so you know precisely how much yeast to pitch. Uses a Neubauer-improved counting chamber and methylene blue. Works for both a slurry and a finished starter.
Materials
- Neubauer-improved counting chamber (haemocytometer) + its coverslip
- Microscope (100–400×)
- Precision pipette (micropipette)
- Test-tube rack with at least 3 tubes (for the dilution steps)
- Distilled or boiled, cooled water (diluent)
- Methylene blue solution (0.01–0.1%)
- Tally counter
- Lint-free wipes + sanitiser
- Yeast sample (homogenised slurry or starter)
Before you start
- Clean the counting chamber and coverslip with a lint-free wipe — no fingerprints or dust on the grid.
- Homogenise the yeast sample well (swirl/shake) so the cells are evenly distributed — otherwise the count is off.
Asepsis isn't critical here (you're not culturing the sample), but clean tools and tubes give a cleaner count.
Step 1 — Dilute the sample
- Dilute in clean tubes from the rack. Thick slurry: 1:100 (1 part sample + 99 parts water). Thin starter: maybe 1:10.
- Aim for the central large square to hold ~100–200 cells (~4–8 per medium square) — too dense is unreadable, too sparse is statistically shaky.
- Note your dilution factor (e.g. 1:100 → factor 100). You need it for the calculation.
Pipette accurately — the dilution is the biggest source of error in the whole method.
Step 2 — Stain (viability)
- Add a drop of methylene blue to the diluted sample and mix gently. Wait 1–2 min.
- Live cells push the dye out and look clear; dead cells take it up and turn blue.
- Viability vs vitality — read more →
Don't wait too long — after a while even live cells take up the dye and viability is underestimated.
Step 3 — Load the chamber
- Place the coverslip over the grid. Touch the pipette tip to the edge of the coverslip and let capillary action draw in ~10 µL. Don't overfill — liquid in the channels, not flooded.
- Let it sit ~3 min so the cells settle into the focal plane.
Step 4 — Count
- Focus on the central large square (1 mm², 25 medium squares) at 100–400×.
- Boundary rule: count cells touching the square's top and left lines (green ✓), but NOT those touching the bottom and right (red ✗) — so you don't double-count.
- Buds: a bud counts as a separate cell if it's ≥ half the mother's size, otherwise as one cell.
- Click live (clear) and dead (blue) separately. Aim for ≥100 cells total for good statistics.
Step 5 — Calculate
- Cells/mL = cells in the central large square × 10,000 × dilution factor. (E.g. 120 cells at 1:100 → 120 × 10,000 × 100 = 1.2 × 10⁸ = 120 million cells/mL.)
- Viability % = live / (live + dead) × 100.
- Total cells = cells/mL × sample volume (mL).
- Counted only some of the 25 medium squares? Scale: cells/mL = (cells / medium squares counted) × 25 × 10,000 × dilution.
- Let the Pitch Calculator do it → under Measured (Haemocytometer) — enter live, dead, squares counted and dilution, and cells/mL and viability fill themselves in. It does step 6 as well — it compares against your target and tells you how many mL to pitch.
Step 6 — Compare to your pitch
- Look up your target cell count in the Pitch Calculator (batch volume × OG × pitch rate) and compare with your total.
- Account for viability — pitch by live cells (total cells × viability %).
Methylene blue overestimates viability, most when it's low – below about 90% (classic home method). Methylene violet is more accurate but harder to find.